comen logo
V3V3Pro-main

V3/V3 Pro

Ventilator

V3/V3 Pro

V3/V3 Pro

Ventilator

The V3 Pro is a powerful yet portable ICU ventilator, featuring turbine-driven technology, a hidden carry handle, and extended battery life for true mobility. It supports a full range of patients from neonates to adults, offers advanced ventilation modes, and comes equipped with comprehensive clinical support tools.

Impressive Ventilation Performance

With 18 ventilation modes and high flow oxygen therapy, V3 Pro provides full patient support throughout their treatment journey, from admission to discharge. Our ventilators can assist patients in various stages, from intubation to weaning, invasive to non-invasive ventilation, and even during high-flow oxygen therapy. Our V3 Pro ventilator will meet all your needs without switching between different devices during recovery.

Impressive Ventilation PerformanceImpressive Ventilation Performance
Impressive Ventilation Performance

Improved Human-Machine Synchronization

Brand new iV-Cycle technology gives V3 Pro the ability to intelligently sense patient's demand for each breath and greatly improves man-machine synchronization in both inspiration and expiration.

Transcends Cinical Boundaries

Engineered for dynamic healthcare environments, V3Pro ventilator offers clinical adaptability through its all-in-one portability concept. Featuring an ultra-lightweight design, endurance-optimized power system, and one-button mobility solutions, it seamlessly serves ER interventions, ICU treatments, intra-hospital transfers, and routine care scenarios, ensuring uninterrupted respiratory support across care continuum.

Transcends Cinical BoundariesTranscends Cinical BoundariesTranscends Cinical Boundaries
Super Light Weight

Super Light Weight

V3 Pro’s weight is down to 10kg, easy to carry and operate

Longer Battery Life

Longer Battery Life

V3 Pro’s battery supports up to 6.6h ventilation

Hidden Handle

Hidden Handle

Designed with a hidden handle that blends seamlessly into the body, this space-saving feature lets you grab and go whenever you need

Internal Turbine Charged

Internal Turbine Charged

Integrated high-performance turbine provides pneumatic ventilation without air supply

Higher Mobility Trolley

Higher Mobility Trolley

V3 Pro can be mounted both on trolley or transportation bed

Super Light Weight

Super Light Weight

V3 Pro’s weight is down to 10kg, easy to carry and operate

Longer Battery Life

Longer Battery Life

V3 Pro’s battery supports up to 6.6h ventilation

Hidden Handle

Hidden Handle

Designed with a hidden handle that blends seamlessly into the body, this space-saving feature lets you grab and go whenever you need

Internal Turbine Charged

Internal Turbine Charged

Integrated high-performance turbine provides pneumatic ventilation without air supply

Higher Mobility Trolley

Higher Mobility Trolley

V3 Pro can be mounted both on trolley or transportation bed

Super Light Weight

Super Light Weight

V3 Pro’s weight is down to 10kg, easy to carry and operate

Longer Battery Life

Longer Battery Life

V3 Pro’s battery supports up to 6.6h ventilation

Hidden Handle

Hidden Handle

Designed with a hidden handle that blends seamlessly into the body, this space-saving feature lets you grab and go whenever you need

Internal Turbine Charged

Internal Turbine Charged

Integrated high-performance turbine provides pneumatic ventilation without air supply

Higher Mobility Trolley

Higher Mobility Trolley

V3 Pro can be mounted both on trolley or transportation bed

Lung ProtectionVentilation Strategy

As our understanding of mechanical ventilation and its potential for lung injury evolves, new concepts have emerged over time. From "volumetrauma" and "barotrauma" first introduced in 1985, to the "low tidal volume ventilation" strategy in the early 21st century, and more recently, "stress and strain," our comprehension of protective ventilation continues to develop. In response to these advancements, Comen is constantly optimizing our functionalities to reduce the burden on healthcare professionals while ensuring patient safety.

Comprehensive Assessment of Ventilator-Related Factors Impacting Lung Injury

To understand the multifaceted influences of mechanical ventilation on lung injury, it is critical to monitor:

Mechanical Power Monitoring

V3 Pro monitors real-time mechanical power, guiding the individualized mechanical strategy.

Driving Pressure Monitoring

Driving pressure (ΔP) predicts ventilator-induced lung injury risk, guiding tidal volume/PEEP optimization to reduce alveolar overdistension in ARDS.

Mechanical Power Monitoring

Low Tidal Volume Ventilation

Low tidal volume ventilation is at the core of current lung-protective ventilation strategies. The recommended tidal volume typically ranges from 6-8 ml/kg (based on ideal body weight) to minimize VILI.

Tidal Volume Recommendation

To adjust tidal volume based on ideal body weight.

Tidal Volume Recommendation

C20/C

To provide monitoring to assess lung expansion and prevent excessive tidal volumes.

C20/C

Personalized PEEP Titration

Appropriate (PEEP) helps maintain alveolar patency and prevents atelectasis. The selection of PEEP should be tailored to each patient’s individual condition, achieving optimal gas exchange while minimizing lung injury.

Static P-V loop

Utilize a pressure-volume tool for individualized assessment.

Static P-V loop

Stress Index

To further evaluate the compliance of respiratory system.

Stress Index

Recruitment Maneuver

Recruitment strategies intermittently increase airway pressures to reopen collapsed alveoli that have suffered from inadequate ventilation.

Sigh

To use sigh maneuvers to facilitate recruitment.

Sigh

Sustained Inflation

To employ sustained inflation techniques for effective recruitment.

Sustained Inflation

Comprehensive Assessment of Ventilator-Related Factors Impacting Lung Injury

To understand the multifaceted influences of mechanical ventilation on lung injury, it is critical to monitor:

Mechanical Power Monitoring

V3 Pro monitors real-time mechanical power, guiding the individualized mechanical strategy.

Driving Pressure Monitoring

Driving pressure (ΔP) predicts ventilator-induced lung injury risk, guiding tidal volume/PEEP optimization to reduce alveolar overdistension in ARDS.

Mechanical Power Monitoring

Low Tidal Volume Ventilation

Low tidal volume ventilation is at the core of current lung-protective ventilation strategies. The recommended tidal volume typically ranges from 6-8 ml/kg (based on ideal body weight) to minimize VILI.

Tidal Volume Recommendation

To adjust tidal volume based on ideal body weight.

Tidal Volume Recommendation

C20/C

To provide monitoring to assess lung expansion and prevent excessive tidal volumes.

C20/C

From Experience-Driven to Data-Powered

Reliable Weaning Tool

RSBI

Rapid Shallow Breathing Index

SBT

Spontaneous Breathing Trial

NIF

Negative Inspiratory Force

P0.1

Airway occlusion pressure at 0.1 second

An SBT is a clinical procedure used to assess a patient's ability to breathe spontaneously and independently without the support of mechanical ventilation. It is a crucial step in the process of weaning a patient from the ventilator.

Innovative HFNC Evaluation Tool

Collecting data from high-flow oxygen therapy patients for accurately assessing the prognosis status of ARDS. When there is no arterial blood gas analysis, the oxygenation index will assist in the prediction and prognosis judgment of respiratory diseases.

Innovative HFNC Evaluation Tool

Precision Calculation

Energy Metabolism Calculation

It enables personalized nutrition plans, preventing under-/over-nutrition support while enhancing recovery.

Innovative HFNC Evaluation Tool
Alveolar Ventilation Calculation

By measuring alveolar dead space, tidal volume, and oxygenation index, it helps clinicians evaluate effective ventilation.

Innovative HFNC Evaluation Tool

Hassle-Free Maintenance

Tired of These Maintenance Headaches?

Tired of These Maintenance Headaches?

Stressing about cross-infection after every use?
Chasing consumables that never last?
Drowning in calibration logs every month?
Nervous about turbo maintenance?
Tired of These Maintenance Headaches?
Relax! V3pro Has Your Back.

Relax! V3pro Has Your Back.

20,000 Hours of “Set It & Forget It”

Modular turbo cartridge: One-click removal, no tools needed.2.3 years (20,000 hours) of continuous runtimeSmart alerts: Proactive notifications for turbine servicing

20,000 Hours of “Set It & Forget It”

High-performance turbine

Infection Control, Simplified in Seconds

Autoclave it or soak it: High-temp sterilization and chemical disinfection kill hidden biofilms. Every breath starts 100% clean.No tools, no fuss: Two-step snap-off design. Swap valves solo in 5 seconds flat.

Infection Control, Simplified in Seconds

Dual valves for inhalation and exhalation

Consumables? More Like “Can’t-Bother-ables”

Zero Calibration, Zero Replacements: Lifetime use without recalibration or consumable purchases.Factory-Calibrated Precision: Ready for accurate operation upon startup—no annual calibration required.5+ Years of Durability: Engineered for relentless performance

Consumables? More Like “Can’t-Bother-ables”

Non-comsumable ultrasonic oxygen sensor

20,000 Hours of “Set It & Forget It”

Modular turbo cartridge: One-click removal, no tools needed.2.3 years (20,000 hours) of continuous runtimeSmart alerts: Proactive notifications for turbine servicing

20,000 Hours of “Set It & Forget It”

High-performance turbine

Infection Control, Simplified in Seconds

Autoclave it or soak it: High-temp sterilization and chemical disinfection kill hidden biofilms. Every breath starts 100% clean.No tools, no fuss: Two-step snap-off design. Swap valves solo in 5 seconds flat.

Infection Control, Simplified in Seconds

Dual valves for inhalation and exhalation

Back to Top
Contact UsContact Us